Rafter Load Calculator

Enter snow, dead, and live loads to get the design load in psf, the per-rafter line load in plf, and a suggested rafter size — verified for deflection and shear, with a step-by-step worksheet you can copy.

⚡ Snow → size in one pass📐 Deflection L/180–L/480⚖️ Shear & bearing checks📋 Copy load worksheet

Rafter Load Calculator

Work top to bottom: set the snow environment, pick the roof assembly, enter the run — the dashboard walks the full load chain and names the rafter size.

🎛️ Inputs

psf

From your local snow map. Use 0 for no snow design load.

psf

Code light storage = 10 psf. Boxes and holiday gear.

Includes sheathing and typical insulation allowance.

ft

📊 Load Chain Results

Suggested rafter

2x10

Bending margin 56% above requirement · #2 grade @ 16" o.c.

Roof snow = 40 × 1 × 1 × 140.0 psf
Governing variable load (snow > 20 psf live)40.0 psf
Dead load15 psf
Design load (total)55.0 psf
Line load @ 16" o.c.73.3 plf
Bending moment M = wL²/8 @ 12'1320 ft-lb
Required S (Fb′ = 1273 psi)13.69 in³

Deflection

PASS

0.27" / 0.40"

Shear

PASS

48 / 135 psi

Self weight

2.41 plf

2x10

How to Calculate Rafter Load, Step by Step

The dashboard automates seven steps, but knowing the chain is what lets you challenge a plan-sheet number on site. Each step below carries the load of the one before it — skip the snow conversion and the whole sizing collapses.

1.Inventory the dead load

CRITICAL STEP≈ 3 min

Weigh everything nailed to the rafters permanently: shingles (15 psf for asphalt, 7.5 for metal, 18 for clay tile), sheathing (2.5–3 psf), insulation, and any mechanicals hung below. Do not guess at tile — a clay roof at 18 psf doubles the dead load of metal and flips the required rafter size on the same span.

Common mistake: Forgetting the sheathing and insulation layer (~3 psf) — it quietly consumes 6% of a rafter's bending capacity.

2.Convert ground snow to roof snow

CRITICAL STEP≈ 2 min

Roof snow load = ground snow × Ce × Ct × Cs. Exposure Ce is 0.9 open, 1.0 normal, 1.2 sheltered; thermal Ct is 1.0 heated, 1.1 minimally heated, 1.2 unheated. The slope factor Cs drops below 1.0 only on steep, slippery, unobstructed planes — for most pitched roofs plan Cs = 1.0 and let the exposure and thermal factors do the work.

Common mistake: Using the ground snow number straight onto the roof when the structure is unheated — a barn at Ct 1.2 carries 20% more than the garage next door on the same snow map.

3.Add live and storage loads

≈ 2 min

Roof live load (20 psf standard) and snow load do not stack — code takes the larger of the two, so in snow country snow governs and live load drops out. Attic storage is different: it adds to the roof load combination because it rides on the same framing. 10 psf storage over a 40 psf snow zone means the rafters see 50 psf of variable load plus dead.

Common mistake: Adding 20 psf live load on top of 40 psf snow — the combination is not required and oversizes rafters by a full size.

4.Convert psf to per-rafter line load

≈ 1 min

Line load (plf) = design load psf × spacing ÷ 12. At 55 psf and 16" o.c., each rafter carries 55 × 16/12 = 73.3 plf. At 24" o.c. the same roof loads each rafter at 110 plf — spacing out 8" moves 50% more load onto every stick, which is why 24" o.c. and heavy snow rarely coexist in the same plan.

Common mistake: Computing the tributary width as spacing instead of spacing ÷ 12 — the line load comes out 12× high.

5.Reverse-size the rafter by bending

CRITICAL STEP≈ 4 min

Bending moment M = wL²/8 with w in plf and L = horizontal run in feet. Required section modulus S = M × 12 ÷ Fb′, where Fb′ is the species base value multiplied by 1.15 (snow duration Cd), 1.15 (repetitive member Cr), and the size factor Cf. The dashboard walks 2x4 → 2x12 and returns the first size whose S ≥ Sreq — that is your working size, pending the two verification steps below.

Common mistake: Skipping the adjustment factors — raw Fb of 875 psi without Cd and Cr underestimates capacity by about 32% and forces an oversize.

6.Verify deflection

VERIFICATION≈ 2 min

Deflection Δ = 5wL⁴ ÷ (384EI), with w converted to lb/in and L to inches. The limit depends on what hangs below: L/180 for exposed rafters, L/240 for unfinished ceiling, L/360 under finished drywall. If the chosen size fails deflection while passing bending, step up a size — stiffness (E and I), not strength, usually governs long, lightly loaded rafters.

Common mistake: Checking deflection at L/240 when a finished ceiling is planned — cracks telegraph through the drywall within the first heavy snow season.

7.Verify shear and bearing

VERIFICATION≈ 2 min

Max shear V = wL/2 at each bearing, and applied shear stress fv = 1.5V ÷ (b × d) must stay under the species allowable Fv. Also check the birdsmouth bearing length: reaction ÷ (Fc⊥ × rafter width) gives the required seat, typically 1.5" for light roofs and up to 2.5" for heavy snow loads on narrow walls.

Common mistake: Overcutting the birdsmouth past 1/3 depth to chase bearing length — it fails the shear check the notch just created. Widen the wall plate or lower the pitch instead.

Roof Load Types: Dead, Live, Snow, and Storage

Every number the calculator produces is one of four load types, and mixing them up is the root of most sizing errors. Dead load is the roof assembly itself — constant, permanent, measured in psf of plan area. Live load is transient human-scale weight: 20 psf standard roof live load for construction and maintenance access. Snow load is the environmental variable, derived from the ground snow map and adjusted for exposure and heat. Storage load is a live load that behaves like a permanent tenant — attic boxes at 10 psf stack with snow because both can exist on the same winter day.

The combination rule is the one to memorize: dead always applies; snow and roof live load are alternatives (the larger governs); storage adds. A warm-climate roof designs at dead + 20 psf live; a snow-belt roof designs at dead + snow (+ storage). This is why a 40 psf snow zone barely changes a rafter size versus a 20 psf live-load roof — 40 psf snow replaces 20 psf live, adding only 20 psf net.

Loads in a rafter also travel as forces, not just pressures. The psf value becomes a line load (plf) through the tributary width, the line load becomes a bending moment and a shear through the span, and the moment becomes a required section modulus through the allowable bending stress. Every step of that chain is reversible — which is exactly what a load-to-size calculator does in reverse of a span table.

How to Calculate Rafter Snow Load

The rafter snow load calculator chain is roof snow = Pg × Ce × Ct × Cs. Ground snow Pg comes off the local map — it is a ground measurement, weighted for drift history, not a roof number. The exposure factor Ce rewards open, wind-swept sites (0.9) where wind scours roofs clean and penalizes sheltered hollows (1.2) where drifts accumulate. The thermal factor Ct acknowledges that heat escapes through the roof and melts snow: a heated house carries 1.0, an unheated barn 1.2.

The slope factor Cs

Cs drops below 1.0 only for steep, slippery, unobstructed roof surfaces — metal on a 12/12 plane with nothing above it can take credit for snow sliding off before it accumulates. For most pitched residential roofs the surface is either not slippery (asphalt) or not unobstructed (valleys, chimneys, adjacent walls), so plan Cs = 1.0 and take no reduction. Unvented-cathedral metal roofs in deep snow country deserve an engineer's eye precisely because the Cs credit is tempting and fragile.

Worked snow conversion

60 psf ground snow, sheltered site (Ce 1.2), heated house (Ct 1.0): roof snow = 60 × 1.2 × 1.0 = 72 psf. The same 60 psf in an open suburb with a heated house: 60 × 1.0 × 1.0 = 60 psf. The sheltered barn version: 60 × 1.2 × 1.2 = 86.4 psf — 44% heavier than the suburban house on identical spans. This is why two buildings side by side on the same street can legally frame different rafter sizes from the same snow map.

How to Calculate Rafter Dead Load

A rafter dead load calculator is really an inventory exercise. Start with the roofing material: metal panels at 1–1.5 psf plus purlins land near 7.5 psf total; three-tab or architectural asphalt with felt lands at 15 psf; cedar shake at 12; clay or concrete tile at 18 or more. Add roof sheathing — 7/16" OSB or 1/2" plywood runs 2.5–3 psf. Add insulation and ceiling finish if a ceiling hangs from the rafters: batt insulation plus drywall contributes 2–5 psf. The standard planning values in the dashboard's dropdown already bundle these allowances.

Dead load earns special attention in two cases. First, re-roofs that add layers: asphalt over asphalt pushes dead from 15 toward 18 psf, and the rafters were sized for the original number. Second, solar: panels plus racking add 3–6 psf distributed and up to 45 psf point loads at the attachment feet. A metal roof at 7.5 psf has 7.5 psf of headroom before it reaches the asphalt baseline — one reason solar-on-metal goes through review faster than solar-on-tile.

Rafter Weight Calculator: Self-Weight by Size and Species

The rafters are part of their own dead load, and a roof rafter weight calculator makes the number concrete: weight per foot = cross-section (b × d) ÷ 144 × density. Densities at 12% moisture content run about 25 lb/ft³ for Spruce-Pine-Fir, 34 for Douglas Fir-Larch, and 37 for Southern Yellow Pine. The table below covers the standard framing sizes.

SizeSection (in²)#2 SPF (plf)#2 DF-L (plf)#2 SYP (plf)Weight of a 14' SPF member
2x45.250.911.241.3513 lb
2x68.251.431.952.1220 lb
2x810.881.892.572.7926 lb
2x1013.882.413.283.5734 lb
2x1216.882.933.984.3441 lb

Practical reading: a 2x6 SPF rafter weighs 1.30 plf, so a 12-footer is 15.6 lb — one-person carry. Everything from a 2x10 up in SYP crosses 40 lb for a 14-footer and wants two carriers or a material lift, which is a real scheduling input, not trivia. Self-weight also feeds the dead-load side of the chain: on a wide-spaced heavy-tile roof, rafter self-weight can add nearly a full psf to the assembly.

Deflection Limits: L/180 to L/480 and the 2x6 Example

Strength keeps a rafter from breaking; deflection keeps it from looking and feeling broken. The formula is Δ = 5wL⁴ ÷ (384EI), and the limit is a ratio of the span: L/180 through L/480. Pick the limit from what hangs below the rafters — the table lists the standard set.

LimitUse WhenAt a 10' Run
L/180Roof with no ceiling below — sag is visible but cosmetic10' run → 0.67"
L/240Ceiling attached but not finished (drywall screws only)10' run → 0.50"
L/360Finished ceiling — plaster or drywall with tape/finish10' run → 0.33"
L/480Brittle finishes, tile, or engineered spans under plaster10' run → 0.25"

Calculating deflection in a 2x6 rafter

Take the worked case from the dashboard defaults: 40 psf ground snow, 15 psf dead, 16" o.c., 12' run, #2 SPF. Design load 55 psf → line load 73.3 plf = 6.11 lb/in. A 2x6 has I = 20.8 in⁴ and SPF has E = 1,300,000 psi, so at L = 144": Δ = 5 × 6.11 × 144⁴ ÷ (384 × 1,300,000 × 20.8) = 0.95". The L/360 limit at 12' is 0.40" — the 2x6 fails stiffness by 2.4× even though its bending margin looks plausible. The dashboard's 2x10 (I = 98.9, 4.8× stiffer) passes at 0.20". That is the deflection check doing its job.

Note the asymmetry worth remembering: I scales with the cube of depth, so each size step roughly doubles stiffness while strength (S) grows only ~60%. Long spans are stiffness problems; short, heavily loaded spans are strength problems. When a suggested size passes bending but fails deflection, the fix is always depth — never a stronger species grade, which raises Fb without touching E by more than ~23%.

Shear and Bearing: The Equations to Calculate Rafter Shear

Two checks close out the chain. Shear: maximum vertical force at each bearing is V = wL ÷ 2, and the rectangular-section stress is fv = 1.5V ÷ (b × d) against the species allowable Fv — 135 psi for #2 SPF, 180 for Douglas Fir-Larch, 175 for Southern Yellow Pine. Bearing: the reaction at the birdsmouth seat must fit into the wood crushing limit perpendicular to grain (Fc⊥ ≈ 335–625 psi by species), which sets a minimum seat length of reaction ÷ (Fc⊥ × rafter width).

On typical residential spans shear passes with huge margin — the worked example above runs 61 psi against 135 allowable. Where shear actually bites is at the birdsmouth: the notch removes wood exactly where shear peaks. That is why the depth limit on the notch (1/3 of rafter depth remaining below it) is a shear provision, and why an overcut birdsmouth on a snow-load rafter is a genuine structural defect, not a cosmetic one. If bearing length falls short, widen the top plate to a 2x6 or add a kicker wall — do not deepen the notch.

Rafter Purlin Calculator: Cutting the Span in Half

When the span outgrows every solid-sawn answer, a rafter purlin calculator problem is the next move: an intermediate beam perpendicular to the rafters, carried on struts down to an interior bearing wall. Bracing rafters at midspan cuts the bending moment to about a quarter of the unsupported case and deflection to roughly a sixteenth — one purlin line turns a "beyond 2x12" span back into a 2x8 conversation.

Purlin Load Path

PURLINstrutstrutinterior bearing wallhalf-span Ahalf-span Bsnow load travels: rafter → purlin → strut → bearing wall

The purlin intercepts rafter loads at midspan and reroutes them to an interior bearing wall — the rafters now span half as far, carrying a quarter of the moment.

Size the purlin like a floor joist carrying the tributary roof load from the rafters that frame into it, strut it every 4' maximum back to bearing, and detail the strut connections — a purlin without a continuous load path to the ground is decoration. In pole-barn framing, purlins run the other job: they span between trusses to carry the roof panels, at 24" o.c. for standard 29-ga metal, and the same tributary-load arithmetic sizes them.

Common Rafter Load Scenarios and the 40 PSF Live Load Table

The scenario table below bundles the load cases this page gets asked about most, including the classic 40 psf live-load and 40 psf snow cases. Sizes are planning anchors for #2 SPF at 16" o.c. — run your exact numbers through the dashboard before ordering lumber, and treat the table as the sanity check, not the answer.

ScenarioDeadSnowLive / StorageDesign TotalSize Anchor (16" o.c.)
Mild climate gable — asphalt shingles15 psf0 psf (none)20 psf35 psf2x6 to 10' run · 2x8 to 13'6" · 2x10 to 17'
Snow belt — 40 psf ground snow, asphalt15 psf40 psf (Ce 1.0)—55 psf2x8 to 11' run · 2x10 to 14' · 2x12 to 17'
Snow belt — 70 psf ground snow, metal7.5 psf70 psf (Ce 1.0)—77.5 psf2x10 to 12' run · 2x12 to 14'6" · I-joists beyond
Storage attic over garage — 40 psf ground snow15 psf40 psf10 psf storage65 psf2x10 to 12' run · 2x12 to 14' · verify framing below
Clay tile roof, no snow18 psf020 psf38 psf2x8 to 10' run · 2x10 to 13'6" — check bearing
Unheated pole barn — 40 psf ground snow, metal7.5 psf48 psf (Ct 1.2)—55.5 psf2x8 to 10'6" run · 2x10 to 14' — purlins 24" o.c.

Pre-Cut Load Checklist

Tick through the list before the lumber order goes in. The progress bar tracks your completion; the reset button clears it for the next job.

0/8 · 0%

Frequently Asked Questions

How does the rafter load calculator work?▼

The rafter load calculator takes your ground snow load, exposure and thermal factors, dead load from the roofing assembly, optional attic storage, rafter spacing, and horizontal run, then works the load path end to end: ground snow × Ce × Ct × Cs gives roof snow; snow (or 20 psf live load, whichever governs) plus dead plus storage gives the design load in psf; design load × spacing ÷ 12 gives the per-rafter line load in plf. From there it reverse-sizes the rafter by bending (S = M×12 ÷ Fb′ with NDS adjustment factors), then verifies deflection against your ceiling limit and checks shear against the species allowable. The output is a suggested 2x4–2x12 size with the full load chain displayed.

How do I calculate rafter snow load?▼

Roof snow load = ground snow load × exposure factor Ce × thermal factor Ct × slope factor Cs. Ground snow comes from your local snow map (ASCE 7 Figure 7.1 or the local amendment). Ce is 0.9 for exposed terrain, 1.0 for normal suburbs, 1.2 for sheltered sites; Ct is 1.0 heated, 1.1 minimally heated, 1.2 unheated; Cs is 1.0 for most pitched roofs and drops only on steep slippery unobstructed planes. Example: 50 psf ground snow, suburban heated house → 50 × 1.0 × 1.0 × 1.0 = 50 psf roof snow. An unheated barn next door carries 50 × 1.2 = 60 psf on identical framing.

How do I calculate rafter dead load?▼

Dead load is the constant weight of the roof assembly: add the roofing material (metal 7.5 psf, cedar shake 12 psf, asphalt shingle 15 psf, clay or concrete tile 18 psf), plus sheathing about 2.5–3 psf, plus insulation and ceiling finish roughly 1–5 psf. A standard asphalt roof lands at 15 psf, a metal roof at 7.5 psf. Do not include furniture, people, or snow — those are live loads handled separately. The dead load number matters most for tile roofs, where 18 psf against 7.5 for metal nearly doubles the constant the rafter carries before a single flake of snow falls.

Does the rafter snow load include the live load too?▼

No — roof live load and snow load are alternatives, not additions. The code load combination takes the larger of the two: 20 psf live load governs in warm climates with no snow design load, and snow governs wherever the ground snow load exceeds 20 psf. What does stack on top is attic storage (a 10 psf live load on the attic floor) because storage and snow can coexist on the same rafters. A 40 psf snow zone with light storage designs at 40 + 10 + dead, not 40 + 20 + 10 + dead.

What size rafter do I need for a 40 psf snow load?▼

At 40 psf ground snow, normal exposure, heated structure, 15 psf dead, 16" o.c.: design load = 40 + 15 = 55 psf, line load = 55 × 16/12 = 73.3 plf. A #2 SPF 2x8 carries a 73.3 plf load over roughly an 11' horizontal run before bending or deflection governs; a 2x10 reaches about 14' and a 2x12 about 17'. Step to 24" o.c. spacing and each size drops roughly 25% of its reach — a 2x8 falls to about 9'6". The dashboard computes the exact answer for your run, species, and spacing; the ranges here are planning anchors.

How is deflection calculated for a 2x6 rafter?▼

Simple-span deflection is Δ = 5wL⁴ ÷ (384EI), with w in lb per inch of length and L in inches. A 2x6 (actual 1.5 × 5.5") has I = 20.8 in⁴; #2 SPF has E = 1,300,000 psi. At a 10' run (120") under 46 plf (3.83 lb/in): Δ = 5 × 3.83 × 120⁴ ÷ (384 × 1,300,000 × 20.8) = 0.40". Against the L/360 limit of 0.33" that 2x6 fails for a finished ceiling and passes at L/240 (0.50"). This is typical — a 2x6 often passes bending while failing deflection, which is why stiffness checks are not optional.

What deflection limit should I use for rafters?▼

Match the limit to what is below the rafters: L/180 where rafters are exposed with no ceiling, L/240 for an attic with unfinished ceiling, L/360 where finished drywall or plaster hangs under the framing, and L/480 for brittle finishes or tile ceilings. Snow zones commonly design rafters at L/360 even with exposed ceilings because the deflection arrives every winter and recovers every spring — repeated cycling is what cracks taped joints. The calculator lets you pick the limit and shows the pass/fail margin in inches for the size it suggests.

How do I calculate rafter shear?▼

Maximum shear sits at each bearing and equals half the line load times the run: V = wL ÷ 2. Applied stress is fv = 1.5V ÷ (b × d), the 1.5 accounting for the rectangular section, compared against the species allowable Fv (135 psi for #2 SPF, 180 for Douglas Fir-Larch, 175 for Southern Yellow Pine). Example: 73.3 plf on a 12' run gives V = 440 lb; on a 2x8 (1.5 × 7.25), fv = 1.5 × 440 ÷ 10.875 = 60.7 psi — comfortable. Shear usually governs only near the birdsmouth on short, heavily loaded rafters, which is why the notch depth limit of 1/3 of the depth is a shear rule as much as a bearing one.

How much does a 2x8 rafter weigh?▼

Weight per foot = cross-section area ÷ 144 × wood density. A 2x8 (1.5 × 7.25 = 10.875 in²) in #2 SPF at about 25 lb/ft³ weighs 10.875 ÷ 144 × 25 = 1.89 plf; in Douglas Fir-Larch at 34 lb/ft³ it weighs 2.57 plf; in Southern Yellow Pine at 37 lb/ft³, 2.80 plf. A 14' SPF 2x8 therefore weighs about 26 lb — two people carry it, but a 16' SYP 2x12 at 5.2 plf runs 83 lb and wants three hands or a lift. The full self-weight table on this page lists every size across the three species groups.

What is a rafter purlin and when do I need one?▼

A purlin is an intermediate beam running perpendicular to the rafters, supported by struts down to an interior bearing wall, that shortens the rafters' effective span. When a cathedral-ceiling rafter fails deflection and there is no ceiling joist to tie to, a purlin line at mid-span cuts the bending moment to a quarter of the unsupported case (M drops from wL²/8 to roughly wL²/32 when braced at midspan). Size the purlin as a floor joist carrying the tributary rafter loads, support it with 2x4 struts every 4' back to a bearing wall, and treat the purlin line — not the ridge — as the rafters' intermediate support.

Can I use this calculator for storage rafter spans in a garage attic?▼

Yes — set attic storage to 10 psf, which is the code's light-storage attic allowance. That value adds to the roof load combination because stored boxes and snow ride the same rafters. For a 40 psf snow zone with 15 psf dead and 10 psf storage: 65 psf total, 86.7 plf at 16" o.c. — a 2x10 spans about 12' there versus 14' without storage. For heavier storage (home gym, workshop shelving), design the attic floor as a floor: 40 psf live load with L/360 deflection, typically meaning doubled rafters or floor joists beside them.

Why does my rafter pass bending but fail deflection?▼

Bending scales with L² (moment = wL²/8) while deflection scales with L⁴ — doubling the run multiplies bending fourfold but deflection sixteenfold. Long, lightly loaded rafters therefore fail stiffness first: a 2x6 at 20' under a light metal roof has plenty of fiber but sags visibly at L/240. The fix is more depth (I grows with the cube of depth — a 2x8 has 2.3× the I of a 2x6), closer spacing, or an intermediate support such as a purlin line. Species changes barely help: E moves from 1.3M to 1.6M across common softwoods, a 23% gain, while one size step doubles it.

Is the roof load the same for a single pitch roof as a gable?▼

The psf is the same, but the span direction differs and changes the strength call. A single-pitch (shed/lean-to) rafter spans the full building width — a 16' wide building loads its rafters across 16' of run, twice the 8' run of a gable rafter on the same building, producing four times the bending moment (wL²/8 with L doubled). Single-pitch rafters therefore size one to two steps larger than gable rafters on the same width, and their strength calculation is the exact case this page's single pitch roof rafter strength calculator handles: enter the full width as the run and read the size.

Loads settled — now cut the rafter

The main Rafter Calculator turns your span and pitch into rafter length, plumb and seat angles, birdsmouth depth, and a printable cut list.

🧮 Open the Main Rafter Calculator

Related Calculators

🪵

Floor Joist Span Calculator

Interactive floor joist span lookup with reference span char...

📐

Roof Pitch Calculator

Interactive roof pitch calculator: convert X/12 to degrees, ...

🔺

Roof Truss Calculator

Roof truss span estimator and selection guide comparing King...

🪚

Rafter Lumber Size Calculator

Free rafter lumber size calculator for rafters, joists & bea...

🏠

Roofing Calculator

Free roofing calculator to estimate roof materials, pitch, r...

🏔️

Roof Height Calculator

Free roof height calculator: enter span and pitch to get rid...

✂️

Rafter Angle Calculator

Free rafter angle calculator: get plumb cut, seat cut, and b...

⛰️

Roof Ridge Height Calculator

Roof ridge height calculator compares Gable, Hip, and Shed r...

🪜

I-Joist Span Calculator

I-joist span calculator with TJI span tables by series, spac...

💲

Roof Truss Cost Calculator

Roof truss cost calculator estimates truss prices per type. ...

📐

Lean-to Roof Calculator

Lean-to roof calculator finds rafter length, pitch, and slop...

🔺

Gable Roof Calculator

Gable roof calculator computes rafter length, plumb cut, roo...

📏

Roof Overhang Calculator

Roof overhang calculator finds eave length, fascia height, a...

🌿

Pergola Rafter Calculator

Pergola rafter calculator finds rafter count, spacing, span,...

🔩

Metal Roof Calculator

Metal roof calculator estimates panel count, panel length, a...

🔗

Rafter Tie Calculator

Rafter tie calculator finds horizontal thrust, tie tension, ...

🏚️

Gambrel Rafter Calculator

Gambrel rafter calculator computes upper and lower rafter le...

⛱️

Gazebo Rafter Calculator

Gazebo rafter calculator sizes hip and common rafters for he...

🏗️

Ridge Beam Calculator

Ridge beam calculator compares ridge board vs structural rid...

📋

Rafter Tables

Rafter table calculator: length factors for 1/12 to 24/12 pi...

🧊

Rafter Insulation Calculator

Calculate insulation R-value, batt depth, and vent baffle ga...

🪵

Board Feet Calculator

Board feet calculator with the bd ft = (T×W×L)/12 formula, n...

📐

Linear to Square Feet Calculator

Convert linear feet to square feet and back with material wi...

🪜

Stair Calculator

Stair calculator finds riser height, tread depth, stringer l...

🏢

Flat Roof Rafter Calculator

Flat roof rafter calculator for low-slope roofs: reference 2...

🪟

Dormer Rafter Calculator

Dormer rafter calculator for shed and gable dormers: rafter ...

🏗️

LVL Beam Span Calculator

LVL beam span calculator with reference span charts by depth...

🚪

Header Size Calculator

Size a door or window header with our free calculator. Door ...

🧱

Wall Stud Calculator

Free wall stud calculator and estimator: stud count with ope...

Educational planning estimates using published reference values for No.2 dimension lumber — not engineering. Verify all loads, sizes, and connections against your local building code and a licensed professional before construction.